ESTABLISHING A RIT TEAM
UPON ARRIVAL AT SCENE
1. PARK THE VEHICLE FAR ENOUGH AWAY FROM THE FIREGROUND TO LEAVE ROOM FOR SUPPRESSION ACTIVITIES
2. THE TEAM REPORTS TO IC
· HOW MANY FF ARE IN AND/OR ON THE BUILDING?
· HOW LONG HAVE THEY BEEN WORKING ON AIR?
· WHAT TYPE OF AIR RACK (S) DO THEY HAVE?
· DO THEY HAVE 30 OR 45 MINUTE BOTTLES?
3. THE RIT TEAM (TWO MEMBERS AT A TIME) PERFORM A SIZE-UP, TAKING NOTE OF
· ENTRANCES/ EGRESSES OF WORKING UNITS
· FIRE CONDITIONS
· BUILDING CONSTRUCTION
· SIZE OF BUILDING
· OCCUPANCY
· FIRE LOCATION
· EXTENT OF FIRE
· PROGRESS OF OPERATION
4. THE RIT TEAM (TWO MEMBERS NOT DOING THE SIZE-UP) SET UP A STAGING AREA
Minimal Equipment:
Orange Tarp (tool placement) Hand line
S.C.B.A./ face-piece (each member) 2216 Spare bottle
S.C.B.A-complete with face piece or RIT bag Irons (Flat head axe/Halligan tool)
Rope 100-ft. minimum Hand lights
Thermo Image camera (if available) Stokes Basket (if available)
1 officer (Team Leader), 3 firefighters 2-Portable radios
5. THE TEAM LADDERS ONE SIDE OF THE BUILDING, AND OR THE ROOF, PROVIDING A SECOND EGRESS FOR WORKING UNITS ON THE SECOND FLOOR AND OR ROOF
6. THE TEAM ESTABLISHES ANOTHER HOSE LINE TO THE ENTRY POINT OF THE MAJORITY OF THE INTERIOR TEAMS, HOOKED UP TO AN ENGINE AND CHARGED (OFFICERS DISCRECTION)
7. THE TEAM MONITORS RADIO CHANNELS FOR (AT LEAST ONE MEMBER IS DEDICATED TO THE RADIO)
· MAYDAY SIGNALS
· CALLS FROM COMMAND
· VISUAL NEEDS FOR TEAM
3. CALL EXTRA FIRE UNITS
4. DETERMINE ENTRY POINT
5. DETERMINE EXTRICATION TOOLS INITIALY NEEDED
6. ONE FIREFIGHTER OR OFFICER ASSISTS COMMAND WITH RIT OPERATION
7. ASSIGN THE FIREGROUND A NEW RADIO FREQUENCY, ASSIGN THE RIT OPERATION TO THE SAME FREQUENCY THE DOWNED FF’S RADIO IS ON
CREW MEMBER ASSIGNMENTS- TEAR
· RADIO TO COMMUNICATE WITH COMMAND/OPERATIONS
· COMMUNICATES PROGRESS AND RECEIVES ORDERS FROM COMMAND
· PROVIDES GUIDANCE TO TEAM MEMBERS INCLUDING THE WAY OUT TO FFs DRAGGING THE DOWNED FF
CREW MEMBER 2 (EXTRICATION)
· IRONS AND/OR OTHER TOOLS SUSPECTED TO BE OF NEED
· WIRE CUTTERS
· FREES THE DOWNED FF FROM OBSTRUCTIONS AND RESTRICTIONS
· ASSISTS WITH AIR BOTTLE SWITCH OVER AND FF REMOVAL
CREW MEMBER 3 (AIR)
· EXTRA AIR SUPPLY, RACK OR RIT BAG DEPENDING ON AVAILABILITY
· ENSURES THE DOWNED FF HAS AN ADEQUATE AIR SUPPLY AND SWITCHES THE AIR SUPPLY TO THE CARRIED IN SUPPLY WHEN NEEDED
· HELPS REMOVE THE DOWNED FF
CREW MEMBER 4 (ROPE)
· SEARCH ROPE
· DEPLOYS THE SEARCH ROPE ON THE WAY IN
· PICKS UP THE SEARCH ROPE ON THE WAY OUT